An electric air valve linkage switch for kitchen range hood ventilation. It integrates the range hood power socket, a test button and the damper connection terminal in one unit. Pressing the button opens the damper and switches on the hood; when the hood stops, the damper closes automatically after a 5-minute delay to clear residual cooking odours.
| Item | Specification |
|---|---|
| Available Sizes / Models | Standard model; custom specifications supported |
| Description | Rated voltage: 220V; Rated power: ≤1000W; Overall dimensions: 95×45×35mm; Built-in wire length: 800mm; Integrated with range hood power socket, test button and wind valve connection terminal; Press button to open damper, automatic closing after 5-minute delay; Plug-and-play design with complete mounting accessories |
| Material / Construction | Flame-retardant ABS housing; pure copper core power cord; high-reliability electrical components |
Controls a motorised damper such as our round electric on/off volume damper, with air exhausted through our stainless steel wall vent cap.
Q: Why is there a delay before the damper closes?
A: The 5-minute delay allows the extract system to clear residual cooking odours before the airway closes.
Q: What is the maximum load?
A: Rated power is up to 1000W at 220V, as listed in the specification table.
Q: How long is the built-in wire?
A: 800 mm, as listed in the specification table.






The southeast corner of the private entrepreneurship park in Huadian Town, Qihui County, Dezhou City, Shandong Province